Phalanx
Human Whole Genome OneArrayTM
Standard Microarray Format:
Human
OneArrayTM
is printed on 1” x 3” (25mm x 75mm) standard
glass slide with barcode
Total
of 32,050 oligonucleotide probes on a single microarray: 30,968
human genome probes and
1,082 experimental control probes
Each
array contains necessary controls for customers to monitor
performance
Each
human target gene is represented by highly specific 60mer
oligonucleotide probe
Open System & Highly Compatible Platform:
Human
Whole Genome OneArrayTM
is compatible with the majority of
commercially available
labeling reagents from Ambion, Clontech, Enzo
Life Science, Invitrogen,
Kreatech, Stratagene, and others
Human
Whole Genome OneArrayTM
can be used with Cyanine 3,
Cyanine 5, and other
compatible dyes
Human
Whole Genome OneArrayTM
is manufactured in a format that
is easily adapted with
existing hybridization methods & systems,
commercial scanners,
analysis systems, and analysis software
packages
Commercial Quality and Performance:
Array to
array reproducibility: average R2
value of same sample
comparison is higher
than 0.95
Dynamic
range: ~2-3 orders of magnitude
Detection
sensitivity: ~0.05pM
User Support:
100%
satisfaction guarantee
Probe
annotation and scanner files
User
manual and supplementary protocols
Easy
access to knowledgeable technical support representatives
Bioinformatics Content:
Phalanx Human Whole Genome OneArray™ employs IMPORT
(INTEGRATED MASSIVE PROBES’ OPTIMAL RECOGNITION TOOL) to select probes
for gene transcript detection by hybridization. The design and
selection of the probe set are based on the following stringent
parameters to deliver the highest specificity and hybridization
efficiency:
Lowest
possible hexamer frequency score
Single base ratio does not exceed 50%
G-C
content ratio is in the range of 40%- 60%
Minimize
single base repeats of 5 or more
Most
probes are located within 1,200bp of the predicted 3’ end of the
transcripts
No
>17 continuous matches with all non-target transcripts
The
difference of melting temperature between probe-to-target transcript
and probe-to-non-target transcripts is >10℃
Majority
of probes show perfect match when blast against genomic
sequence (i.e. within a single exon)
Human Whole Genome OneArrayTM
Content
|
Total number of
gene probes |
30,968 |
|
Entrez Gene Probes
Probes derived from
Unigene build #175 and RefSeq
transcripts that can
be annotated with Entrez ID. |
24,923 |
|
Non-Entrez Gene Probes A
Probes derived from
Unigene build #175 transcripts
that are annotated
with Entrez ID |
3,780 |
|
Non-Entrez Gene Probes
B
Experimentally
selected probes derived from Unigene
build#163
transcripts that are annotated with only gi
number |
2,265 |
Each
Oligonucleotide probe is designed to hybridize to a specific
target
gene described in
the most current public domain contents,
such as Unigene, Cancer
Genome Anatomy Project (CGAP),
BioCarta, Kyoto
Encyclopedia of Genes & Genome (KEGG), and
validated by Human
Genome Sequencing
The
most well known and studied target genes will be the first priority
of probe selection
Contains
1,082 performance monitoring control probes for hybridization,
sample quality, and
labeling reactions
For detailed probe annotation of Human Whole Genome
OneArrayTM,
please refer to Phalanx
OneArrayTM
Support Center:
http://support.phalanxbiotech.com/supportTest/index.html
 |